ASTM D1005 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers

    What is ASTM D1005?

    ASTM D1005 is a standard test method for the thickness of dried films of paint, varnish, lacquer, and related products using micrometers. It provides stationary and hand-held micrometer methods for coatings on plane rigid surfaces and for free films. ASTM D1005 (Standard Test Method for Measuring Dry-Film Thickness of Organic Coatings Using Micrometers) offers a standardized method for measuring dry-film thickness and is recommended for free films and films on laboratory test panels. Therefore, ASTM D1005 data can be used to assess coating thickness and support coating quality and performance.

    Read more

    Get Certified ASTM D1005 Testing for Reliable Dry-Film Thickness Evaluation

    ASTM D1005 testing is a micrometric measurement used to determine the thickness of dried organic coating films. Procedure A uses stationary micrometers, while Procedure B uses hand-held micrometers, allowing engineers to measure coating thickness on rigid surfaces or free films under defined measurement conditions. The results may be used for the evaluation of paint, varnish, lacquer, and other coatings in coating development, quality control, and for comparison with specified thicknesses.

    What is the Scope of the ASTM D1005 Test Standard?

    ASTM D1005 outlines methods for measuring the thickness of dried paint, varnish, lacquer, and other organic coating films with micrometers. For coatings on plane rigid surfaces and for free films, specifications or hand-held micrometers are given. The scope of ASTM D1005 includes:

    Read more

    • Material type: Dried films of paint, varnish, lacquer, and related coating products.
    • Purpose: Determination of dry-film thickness using micrometers.
    • Primary property: Thickness of dried organic coating films.
    • Measurement method: Stationary or hand-held micrometer measurement.
    • Procedure A: Stationary micrometer for coatings applied to plane rigid surfaces.
    • Procedure B: Stationary micrometer for free films.
    • Procedure C: Hand-held micrometer for coatings applied to plane rigid surfaces.
    • Procedure D: Hand-held micrometer for free films.
    • Thickness limitation: Procedures A and C are not recommended for films less than 12.5 μm (0.5 mil) in thickness.
    • Free-film limitation: The minimum thickness for Procedures B and D depends on the thickness required to remove the sample as a free film.
    • Measurement units: SI units are regarded as the standard measurement basis.

    What are the Uses of ASTM D1005 Testing?

    ASTM D1005 testing determines the thickness of dried organic coating films on rigid surfaces or as free films. Therefore, the results may help engineers assess coating application, uniformity, and performance. The ASTM D1005 standard:

    • Measures the thickness of dried organic coating films.
    • Evaluates coatings on plane rigid surfaces.
    • Determines the thickness of free coating films.
    • Assists in testing paint, varnish, lacquer, and other products.
    • Assists in the evaluation of coating thicknesses on laboratory test panels.
    • Helps in the comparison of coating thicknesses for various specimens.
    • Assists with quality control assessments of coatings.
    • Assists in determining the thickness of the coating and whether it complies with the relevant requirements.
    • Provides thickness information for coating performance and development.
    • Compares measurements made with appropriate static or hand-held micrometers.

    Which materials can be tested under ASTM D1005?

    ASTM D1005 applies to dried films of paint, varnish, lacquer, and other coating products that may be measured with a micrometer. If the coating is applied to a plane rigid surface or is prepared as a free film, the appropriate procedure can be chosen based on the configuration of the specimen. The coating should not be easily deformable under the measuring load, as deformability can affect the accuracy and precision of the thickness measurement.

    Why is ASTM D1005 Important?

    ASTM D1005 is significant because dry film thickness is directly related to assessing coating application and performance. When coatings are applied to laboratory test panels, coating deformability and substrate uniformity can affect coating thickness measurements. The standard has clearly specified procedures for stationary and hand-held micrometers and for rigid-surface coatings and free films. Engineers can therefore use the results to assess coating thickness and the choice of supporting material, develop the coating, perform quality control, and evaluate coating performance. However, the coating deformability will make a big difference in the thickness measured. Substrate uniformity and the coating condition during measurement can also affect the measured response.

    ASTM D1005 Equipment and Sample Preparation Guide

    ASTM D1005 requires that the equipment be able to measure the thickness of dried coating films by the applicable stationary micrometer procedure or hand-held micrometer procedure. Depending on whether the coating is to be kept on a plane rigid surface or to be removed as a free film, the type of equipment is different.

    Read more

    Sample and Specimen DetailsDried paint, varnish, lacquer, or related organic coating films applied to plane rigid surfaces or prepared as free films.
    Specimen PreparationTechnicians prepare and condition the coating to ensure that the film is dry enough and appropriate for measurement. The thickness of free films should not be changed by removing, stretching, or tearing.
    Specimen DimensionsASTM D1005 does not specify a single required specimen length or width. Procedures A and C are not recommended for films less than 12.5 μm (0.5 mil) in thickness, while the minimum thickness for Procedures B and D depends on the thickness needed to remove the sample as a free film.
    InstrumentationProcedures A and B use stationary micrometers, including suitable dial comparator or dial indicator arrangements, while Procedures C and D use hand-held micrometers. The applicable measuring surfaces and instruments must provide suitable accuracy for the coating thickness being measured.

    Testing Procedures and Requirements for ASTM D1005

    The technician can use the appropriate micrometer procedure in ASTM D1005 to determine dry-film thickness. Therefore, it is necessary to control specimen preparation, instrument selection, measurement surface, and coating condition during the test. The procedure outlined in ASTM D1005 is as follows-

    Read more

    Specimen PreparationTechnicians prepare and inspect dried coating or free film, and verify that specimens are appropriate for the chosen micrometer procedure.
    Procedure SelectionAnalysts select Procedure A or B for a stationary micrometer and Procedure C or D for a hand-held micrometer, based on the specimen configuration.
    Instrument PreparationThe testing technician sets up and checks the micrometer to ensure the micrometer’s thickness measurements and measuring surfaces are accurate.
    Thickness MeasurementThe technician properly places the micrometer on the coating/free film and calculates the thickness based on the instrument reading.
    Measurement LocationsAnalysts measure at representative points and avoid conditions that could distort the coating or make the measurement unrepresentative.
    Data CollectionThe operator records the individual thickness measurements together with the applicable procedure and specimen information.
    Result ReportingThe engineer’s report contains the specimen description, ASTM D1005 procedure used, measurement results, units, and other pertinent information about the coating and measurement conditions.

    ASTM D1005 Testing Process and Data Collection

    ASTM D1005 testing starts with selecting and preparing a dried coating specimen appropriate for the selected measurement procedure. The specimen is then set for measurement, and the needed stationary or hand-held micrometer is set up. The coating thickness is measured at representative points without excessive deformation of the coating by the technician. In free-film measurements, the film is carefully removed but not altered in thickness. The measuring system then stores the thickness values, and the measured values describe the dry-film thickness of the coating under the selected measurement conditions; the coating thickness can be compared between the specimens if the coating was measured by the same procedures and conditions.

    The image shows an organic coating specimen being measured with a micrometer during ASTM D1005 dry-film thickness testing.
    ASTM D1005 Dry-Film Thickness Measurement of Organic Coatings Using Micrometers.

    Common Challenges and Troubleshooting

    Coating conditions, specimen preparation, instrument selection, and contact with the specimen all affect accurate ASTM D1005 results. The thickness of coatings that are prone to deformation under the force of the micrometer can be difficult to measure, since deformation can cause errors in the thickness measurement and decrease measurement accuracy and precision. When laboratory test panels are coated, uniformity of the substrate should also be taken into account. Thus, proper measurement methods should be used, and distortion should be avoided during the instrument’s positioning. A major concern is the preparation of free films, because the film may be stretched or otherwise damaged and cause the measured thickness to be different. Therefore, it is important that the test team keep the specimen and measuring instrument in the same condition as much as possible during the measurement period.

    ASTM D1005 Analysis Results and Interpretation

    ASTM D1005 results are used to provide information on the dry-film thickness of organic coatings measured with micrometers. Analysts measure the thickness of the coating under the specified measurement conditions and interpret the thickness readings from the applicable procedure to determine the thickness. The data recorded can be used to compare the coatings and to know the differences in the coating thickness. Therefore, these results can be applied to help choose a coating, develop a product, quality control, and evaluate coating performance.

    Read more

    • The laboratory records coating thickness and measurement information to determine the dry-film thickness response.
    • The analyst uses the thickness readings to determine the uniformity of the coating at the locations measured.
    • The laboratory reports results in μm and includes a mils equivalent when necessary, and includes the ASTM D1005 procedure used.
    • Engineers compare the thickness of the coating between specimens subjected to the same measurement procedure and under the same conditions.
    • Analysts use the recorded results to support coating evaluation, product development, quality control, specification assessment, and coating performance evaluation.

    Link to ASTM D1005

    FAQ

    Why is ASTM D1005 important?
    ASTM D1005 is significant since it provides standard methods for measuring the dry-film thickness of paint, varnish, lacquer, and other organic coatings with micrometers.
    Dry-film thickness of organic coatings on plane rigid surfaces and free films can be evaluated by using ASTM D1005.
    ASTM D1005 is a method for measuring the thickness of dried organic coating films with a stationary or hand-held micrometer. The thickness can be given in μm and also in mils, if applicable.

    Updated on September 23, 2026

    Malhar Khole
    About Author
    Malhar Khole is a Material Testing Associate at Matestlab Inc. and holds a postgraduate degree in Material Science and Technology from IIT (BHU), Varanasi.
    Know More
    Testimonials
    Real results
    Engineers trust us with what matters most
    Why Choose Matestlab?
    Matestlab is a unified testing services partner based in the USA. Matestlab offers raw material and product testing services through accredited, expert laboratories primarily based in the USA. Matestlab supports physical, thermal, chemical, electrical, mechanical, environmental, and characterization testing needs through its global network of 2200+ accredited testing laboratories. Matestlab's in-house materials science experts curate and design comprehensive testing programs matched to the sample material and specific testing need, with regulatory requirements and confidentiality in mind.

    If you are looking for a managed and trusted testing partner to achieve your research goals, feel free to schedule a meeting with us or send us a request at connect@matestlabs.com to learn more about our services. For a quick quote, call us at (302)244-7710. We are happy to serve you.
    Start Your Testing
    Project Today
    Define your requirements and get access to
    specialized laboratories ready to deliver results
    Partners with us
    Clients
    Vendors
    Process for testing
    • STEP 01

      You share your testing requirements

    • STEP 02

      You share your sample(s)

    • STEP 03

      We deliver your test reports

    Get your testing done

    Let us know your testing requirements and we will be right back with a solution.

      Let us root for each other. Collaborate to grow, expand, and accelerate our businesses.

      Partner with us