ASTM D618 Testing: Is Your Plastic Sample Conditioned Correctly Before Testing?

Introduction

Plastics are very susceptible to the environment, especially temperature and moisture. Such properties as tensile strength, impact resistance, dimensional stability, and electrical behaviour may vary greatly when a specimen is tested immediately after being moulded, machined, or stored under non-controllable conditions. ASTM D618 standard practice for conditioning plastics for testing provides guidelines to use a uniform method to prepare plastic samples before testing. 

Purpose of ASTM D618 Conditioning

ASTM D618 is mainly aimed at pretesting plastic test samples by taking them to a known and reproducible condition. Conditioning makes sure that the moisture content and temperature are constant, such that test results indicate intrinsic material properties. The criterion determines the proper conditioning of a sample by specifying certain environments and conditioning time.

Standard Conditioning Atmospheres

ASTM D618 is a standard that defines atmospheres common to plastic conditioning. Conditions of 23 + 2°C and 50 + 10 per cent relative humidity are the most frequently used and commonly known as the standard laboratory atmosphere. When necessary due to the specification of the material or the method of the test, alternative conditioning environments may be implemented, e.g., dry or high-humidity conditions. The atmosphere used should never be missed out and should be reported with the test results.

Conditioning Time Requirements

ASTM D618 requires conditioning of specimens for at least 40 hours in the given atmosphere, unless otherwise stated in the test method or fabric specification used. This length allows the plastic to stabilise with the surroundings. In the case of moisture-sensitive plastics, conditioning may additionally require an extended time to provide constant results.

Specimen Handling Before and After Conditioning

Sample pieces must not be contaminated on the surface, have residual stresses, or be too hot due to machining or moulding before conditioning. Sampling should be done after conditioning by ensuring samples are maintained such that they are not exposed to uncontrolled conditions before being tested. The testing ought to be done immediately after leaving the conditioning chamber to ensure that the environment is consistent.

Verification of Correct Conditioning

The study of ASTM D 618 defines that a plastic sample is in the correct condition after being exposed to the stated atmosphere within the required time and kept in that condition until the time of the test. Equilibrium may be checked by mass stability checks or moisture content checks, particularly in highly hygroscopic materials like nylon.

Common Conditioning Mistakes

Common statistical errors are inadequate conditioning time, wrong humidity control, conditioning specimens at the incorrect temperature, or letting samples equilibrate in uncontrolled laboratory air and then testing them. These errors may result in a considerable scattering of test data and ineffective characterization of the material.

Importance of ASTM D618 Compliance

The use of ASTM D618 will guarantee uniformity, consistency, and comparability of the test results of plastics across different laboratories.  In a word, ASTM D618 provides an answer to the question of proper sample preparation and is one of the pillars of plausible plastic testing.

Davis Scott
Davis Scott is an Electrical and Electronics Engineer specializing in multidisciplinary validation, quality assurance, and comprehensive electro-mechanical testing.
Know More
Resources
Recent blogs
Testimonials
Real results
Engineers trust us with what matters most
Why Choose Matestlab?
Matestlab is a unified testing services partner based in the USA. Matestlab offers raw material and product testing services through accredited, expert laboratories primarily based in the USA. Matestlab supports physical, thermal, chemical, electrical, mechanical, environmental, and characterization testing needs through its global network of 2200+ accredited testing laboratories. Matestlab's in-house materials science experts curate and design comprehensive testing programs matched to the sample material and specific testing need, with regulatory requirements and confidentiality in mind.

If you are looking for a managed and trusted testing partner to achieve your research goals, feel free to schedule a meeting with us or send us a request at connect@matestlabs.com to learn more about our services. For a quick quote, call us at (302)244-7710. We are happy to serve you.
Start Your Testing
Project Today
Define your requirements and get access to
specialized laboratories ready to deliver results
Partners with us
Clients
Vendors
Process for testing
  • STEP 01

    You share your testing requirements

  • STEP 02

    You share your sample(s)

  • STEP 03

    We deliver your test reports

Get your testing done

Let us know your testing requirements and we will be right back with a solution.

    Let us root for each other. Collaborate to grow, expand, and accelerate our businesses.

    Partner with us