ASTM E1300 is a standard practice for calculating the load resistance of specific glass constructions and types under a uniform lateral load for a short or long duration. It is used for vertical and sloped glazing in buildings that fall under the following combined design-load limit. The scope of ASTM E1300 includes:
- Material: Monolithic and laminated glass constructions, including specified combinations of glass types used in sealed insulating glass units.
- Load conditions: Uniform lateral loads associated with wind load, snow load, and self-weight within the practice’s scope.
- Glass configurations: Rectangular glass constructions with continuous lateral support along one, two, three, or four edges, subject to the applicable assumptions.
- Support conditions: Defined edge-support conditions, including simply supported edges that can slip in-plane and specified behavior for glass supported on one or two edges.
- Load duration: Evaluation of load resistance under short-duration or long-duration loading conditions.
- Probability of breakage: Determination of load resistance for a specified probability of breakage using the procedures provided in the practice.
- Insulating glass units: Evaluation of applicable insulating glass constructions with four-sided edge support.
- Deflection evaluation: Use of the practice’s charts and supplementary procedures to estimate maximum lateral glass deflection.
- Design limitations: Application to vertical and sloped building glazing with a total combined magnitude of specified wind load, snow load, and self-weight no greater than 15 kPa (315 psf).
- Exclusions: Wired, patterned, sandblasted, drilled, notched, or grooved glass, and glass with surface or edge treatments that reduce its strength, are outside the stated scope.
What are the Uses of ASTM E1300 Testing?
ASTM E1300 is the standard used for assessing the load resistance of building glass and to help determine the type and thickness of glass to use under certain loading conditions. Therefore, the results can be used by manufacturers, engineers, architects, and quality-assurance staff to evaluate different glass configurations for architectural glazing. The ASTM E1300 standard-
- Calculates the load resistance of various types and constructions of glass for uniform lateral loads.
- Assists in the selection of glass for vertical and sloped glazing in buildings.
- Assesses relevant monolithic, laminated, and insulating glass options.
- Considers both short- and long-duration loads for load resistance.
- Enables the engineer to estimate the likelihood of failure under certain loading conditions.
- Describes and includes procedures and charts for maximum lateral deflection of glass.
- Compares different glass types, thicknesses and edge-support configurations.
- Helps to assess glass design to a given wind load, snow load and self-weight.
- Assists in the design, product development and quality-assurance of building-glazing.
- Supplies technical data for glass selection and indicates conditions where further engineering judgment is required.
Which materials can be tested under ASTM E1300?
ASTM E1300 is applicable to specific monolithic glass, laminated glass, and applicable insulating glass constructions for use in buildings. The practice considers rectangular glass configurations and uniform lateral loading conditions based on data on type of glass, construction, dimensions, support conditions, and load durations. Eligible glass types include annealed glass, heat-strengthened glass, fully tempered glass, and laminated constructions that include eligible glass types. When the insulating glass units meet the construction and four-sided edge-support requirements of the practice, they are covered. There is no single specimen size for the practice for all uses; the size and type of glass and its configuration must be determined for the design under consideration.
Why is ASTM E1300 Important?
The importance of ASTM E1300 is that it offers a consistent engineering method to calculate glass load resistance in buildings. The practice provides methods for the assessment of specified glass constructions subjected to uniform lateral loading and for taking into account the risk of breakage. It features charts and calculation procedures for engineers to determine load resistance and lateral deflection in glass type and thickness selection. Assumptions such as the condition of the glass, edge support, and lack of edge damage or abuse are also important considerations. These requirements are used to achieve uniformity in glass type evaluation, but other factors, such as building codes, safety glazing, thermal stresses, windborne debris, seismic effects, building movement, and other project-specific conditions, should also be considered in the final selection of the glass type. (ASTM E1300-24)