ASTM D7709 Measuring Water Vapor Transmission Rate (WVTR) of Pharmaceutical Bottles and Blisters

    What is ASTM D7709? 

    ASTM D7709 is a standard test method for determining the water vapor transmission rate (WVTR) of pharmaceutical bottles and blisters. This test method measures the amount of water vapor that can enter a tightly closed, sealed package by determining the weight gain of a desiccant placed inside the package. ASTM D7709 (Standard Test Methods for Measuring Water Vapor Transmission Rate (WVTR) of Pharmaceutical Bottles and Blisters) evaluates the moisture barrier capabilities of pharmaceutical container-closure systems and compares different packaging designs. It defines different approaches for bottles, barrier blisters, and quasi-barrier blisters and provides options for assessment of packages for moisture-sensitive pharmaceutical products. 

    Read more

    Get Certified ASTM D7709 Testing for Reliable Pharmaceutical Packaging Performance 

    Pharmaceutical products are sensitive to moisture, which affects stability, efficacy, and shelf-life. This test method assists manufacturers in gaining insights into packaging resistance to moisture influx under standardized conditions. Certified testing helps select the right packaging materials, design new packaging materials, control the quality of packaging materials, and compare packaging products used in pharmaceutical applications. 

    What is the Scope of ASTM D7709? 

    ASTM D7709 is a standard that addresses the measurement of water vapor transmission rate (WVTR) of pharmaceutical bottles and blisters. It can be used for complete products such as bottles, blisters, vials, closures, caps, and more. The test is conducted in a controlled environment and used for quality control and comparison. The scope of ASTM D7709 includes: 

    Read more

    • Material type: Pharmaceutical bottles, blisters, vials, and closures.
    • Purpose: The Dry Film Transfer (DFT) Adhesion Test is used to determine WVTR for a moisture barrier. 
    • Property measured: Water vapor transmission rate (WVTR) in mass of water vapor per unit time per package. 
    • Method: The test involves applying a controlled humidity gradient across the package wall and measuring the amount of water vapor that permeates through. A water vapor transmission rate (WVTR) analyzer is used to track the transmission rate. 
    • Result: WVTR is expressed in water vapor mass per unit time per package (e.g., mg/day/package). 
    • Test Limitations: The standard provides various test conditions and methods. The user should set up procedures suitable for the type of package and test conditions. 
    • Environmental conditions: Tests are performed under controlled temperature and humidity conditions. 
    • Applications: Quality control in the pharmaceutical industry, package development, selection of packaging materials, and shelf-life studies. 

    What are the Uses of ASTM D7709 Testing?

    ASTM D7709 testing helps laboratories assess the moisture barrier performance of pharmaceutical packaging. Engineers then use the results to assess packaging designs and understand the effectiveness of packaging in moisture protection. This standard-

    • Measures the moisture barrier performance of the pharmaceutical package.
    • Aimed at quality assurance in pharmaceutical packaging production
    • Helps in package development and material selection
    • Aids in shelf life studies
    • Compares packaging materials and designs against each other 

    What Materials Can Be Tested Under ASTM D7709? 

    ASTM D7709 applies to pharmaceutical bottles, blisters, and vials. Before starting a testing program, an analyst should decide on the package type, test method, and necessary conditions.  Laboratories test high-barrier multiple-unit containers such as bottles,high-barrier single-unit containers such as formed blisters, and quasi-barrier single-unit blister packages. 

    Why is ASTM D7709 Important? 

    ASTM D7709 specifies a standardized method for assessing how well a closed pharmaceutical container prevents water vapor transport. Moisture-barrier performance is important when manufacturers choose packaging for products that must be protected from environmental humidity. The standard assesses the complete container-closure system, allowing engineers to account for moisture entering the package body, seals, closures, or other components of the assembled package. Reliable WVTR measurements enable manufacturers to distinguish between different barrier packages and make intelligent packaging options throughout development and quality testing. 

    ASTM D7709 Equipment and Sample Preparation Guide

    ASTM D7709 specifies the requirements for a water vapor transmission rate analyzer that measures WVTR under controlled conditions. Laboratories are used to prepare representative samples of pharmaceutical packaging for testing. 

    Read more

    Sample and Specimen DetailsTechnicians use complete pharmaceutical bottles, or blisters closed and sealed with regular closures and caps. 
    Specimen PreparationTechnicians fill each test package with a known amount of desiccant and seal it securely. They prepare the packages as they would be used in actual pharmaceutical packaging, ensuring the closure system is intact 
    Specimen DimensionsThe methods accommodate all consumer-sized primary containers limited only by test equipment and balance capacity. 
    InstrumentationThe test uses a controlled temperature and humidity chamber (typically 40°C/75% RH), high-precision analytical balance, desiccant, and data acquisition software.

    Testing Procedures and Requirements for ASTM D7709  

    This test standard exposes pharmaceutical packaging to prescribed temperature and humidity. The system automatically performs the test while setting the necessary parameters set by the technicians. The ASTM D7709 test methods include the following test procedure:

    Read more

    Package Preparation Technicians fill each pharmaceutical bottle or blister with desiccant and seal it with its closure system. They record the initial weight of each prepared package. 
    Conditioning and Stabilization Technicians place the sealed packages in a temperature and humidity chamber (typically 40 ± 2°C and 75 ± 5% RH). They allow the packages to stabilize under these conditions for a specified period. 
    Weight Measurement Technicians remove the packages at specified intervals and weigh them using a high-precision analytical balance. They record the weight gain resulting from water vapor transmission into the package and subsequent uptake by the desiccant. 
    Data Analysis Technicians calculate the Water Vapor Transmission Rate (WVTR) from the steady-state slope of the weight gain versus time curve. They ensure steady-state conditions are achieved before calculating the final rate. 
    Result Reporting Laboratories report the WVTR in SI units (mg per bottle per day for bottles; mg per blister cavity per day for blisters). They also note test conditions such as temperature and relative humidity, and any deviations from the standard procedure. 

    ASTM D7709  Testing Process and Data Collection

    The analyst selects pharmaceutical packaging samples and determines the test method and conditions. Then, technicians prepare the packaging samples and insert them into the WVTR analyzer. The system controls the packages at the desired temperature and humidity and records the water vapor transmission rate. Technicians calculate the WVTR from the measured data. Analysts record all testing conditions and note any deviations from standard procedures. 

     The image depicts pharmaceutical bottles and blister packages undergoing controlled water vapor transmission rate testing according to ASTM D7709.
    ASTM D7709 Water Vapor Transmission Rate Testing of Pharmaceutical Bottles and Blisters

    Common Challenges and Troubleshooting

    Accurate ASTM D7709 testing needs consistent temperature and relative humidity, reliable package closure, appropriate desiccant preparation, and accurate weighing. Leakage or inadequate closure can increase moisture entry and produce results that do not accurately represent the intended package configuration. Insufficient balancing sensitivity can also have an impact on measurements when packages have very low WVTR values. Technicians double-check balance performance, ambient chamber conditions, package integrity, and weighing processes before and during testing. 

    ASTM D7709 Analysis Results and Interpretation

    The report provides an overview of the rate of water vapor intrusion into the tested pharmaceutical container-closure system. The analyst determines WVTR by the increase in package weight due to moisture absorption by the desiccant inside the package.

    Read more

    • The lab measures WVTR in milligrams per bottle per day (mg/bottle-day).
    • The laboratory provides the WVTR for blisters in mg/cavity-day.
    • The analyst determines the package weight gain during the test period and applies the applicable ASTM D7709 calculation procedure.
    • The engineer can then compare WVTRs of alternative packages to assess differences in moisture-barrier performance.
    • A lower WVTR indicates less water vapor is admitted to the package under the test conditions.
    • The report records the tested package configuration and environmental conditions for users to interpret and compare results. 

    Link to ASTM D7709

    FAQ

    What is ASTM D7709 testing?
    ASTM D7709 establishes standardized procedures for assessing the water vapor barrier performance of closed pharmaceutical bottles and blister packaging.
    ASTM D7709 assesses and compares the water vapor transmission rates of pharmaceutical container closure systems such as bottles, barrier blisters, and quasi-barrier blisters.
    ASTM D7709 determines the water vapor transmission rate (WVTR) of pharmaceutical packaging.

    Updated on September 10, 2026

    Rohit Dhembare
    About Author
    Rohit Dhembare is an Operations Associate at Matestlab Inc., holds a postgraduate degree in Organic Chemistry and is trained in Materials Science testing techniques.
    Know More
    Testimonials
    Real results
    Engineers trust us with what matters most
    Start Your Testing
    Project Today
    Define your requirements and get access to
    specialized laboratories ready to deliver results
    Partners with us
    Clients
    Vendors
    Process for testing
    • STEP 01

      You share your testing requirements

    • STEP 02

      You share your sample(s)

    • STEP 03

      We deliver your test reports

    Get your testing done

    Let us know your testing requirements and we will be right back with a solution.

      Let us root for each other. Collaborate to grow, expand, and accelerate our businesses.

      Partner with us

        Discover more from Matestlab

        Subscribe now to keep reading and get access to the full archive.

        Continue reading