ASTM D6083 Standard Specification for Liquid-Applied Acrylic Coating Used in Roofing

    What is ASTM D6083/D6083M? 

    ASTM D6083/D6083M is a standard specification for liquid-applied, water-dispersed acrylic latex elastomeric protective roof coatings. It defines the coating’s properties as a liquid and the performance of the cured film. The coating is formulated from a water-based acrylic latex elastomeric emulsion polymer together with pigments and other additives that provide the required physical properties. As manufactured, the material is supplied in liquid form and may be applied to a roof surface by brushing, squeegeeing, rolling, or spraying; however, the specification does not provide guidance on application. Liquid-property evaluation includes characteristics such as viscosity and the volume and weight of solids. The cured film is tested for initial elongation at break, initial tensile strength, elongation after accelerated weathering, permeance, water swelling, adhesion, fungi resistance, tear resistance, and low-temperature flexibility after accelerated weathering. ASTM D6083/D6083M (Standard Specification for Liquid-Applied Acrylic Coating Used in Roofing) is therefore used as a standardized basis to assess the performance of acrylic roof coatings against the specified material and cured-film properties.

    Read more

    Get Certified ASTM D6083/D6083M Testing for Reliable Acrylic Roof Coating Evaluation 

    ASTM D6083/D6083M offers standardized requirements for testing liquid-applied acrylic protective roof coatings. Technicians and analysts can test both liquid coating properties and cured film performance. The test covers mechanical, physical, weathering, moisture, adhesion, biological, and low-temperature properties. Reliable results are dependent on proper specimen preparation, calibration of equipment, conditioning, and use of the referenced ASTM test methods.

    What is the scope of ASTM D6083/D6083M?

    ASTM D6083/D6083M is a standard specification that covers liquid-applied, water-dispersed acrylic latex elastomeric protective roof coatings. The specification applies to material as supplied and to the cured film formed from the coating. It sets standards for certain physical characteristics of the liquid or cured film that are selected to represent the performance of the roofing coating.

    Read more

    The scope of ASTM D6083/D6083M includes:

    • Material: Liquid-applied, water-dispersed acrylic latex elastomeric protective roof coatings containing a water-based acrylic latex elastomeric emulsion polymer with pigments and other additives. 
    • Objective: Establish requirements for the liquid coating and the cured film so that the material can be evaluated for specified roofing performance characteristics. 
    • Property measurement: Liquid viscosity, volume and weight of Solids, tensile strength and elongation, Permeance, Water Swelling, Adhesion, Fungi Resistance, Tear Resistance, and low-temperature flexibility after Accelerated Weathering. 
    • Method: The coating and cured film will be tested using the following applicable ASTM test methods referenced by the specification. 
    • Result: Test results are compared with the applicable requirements established by ASTM D6083/D6083M for the liquid material and cured coating film. 
    • Limitations: The specification covers material and performance requirements but does not give roof application instructions or duplicate all conditions that would occur in field service.
    • Environmental conditions: Applicable cured-film evaluations are conducted under specified conditions and accelerated weathering procedures; service conditions may vary from laboratory conditions. 
    • Applications: Roofing systems where physical and weathering performance is specified or assessed for a liquid-applied elastomeric roof coating.

    What are the uses of ASTM D6083/D6083M testing? 

    ASTM D6083/D6083M tests the ability of liquid-applied acrylic roof coatings to meet required physical and performance properties. The specification offers a foundation for evaluating coating characteristics by manufacturers, laboratories, contractors, specifiers, and other users. This standard-

    • Measures the physical characteristics of water-dispersed acrylic elastomeric roof coatings. 
    • Verifies important properties of the liquid coating before use. 
    • Measures the mechanical and physical characteristics of the cured coating film. 
    • Evaluates coating performance following accelerated weathering on appropriate physical property tests 
    • Provides information on adhesion, water swelling, fungal resistance, tear resistance, and low-temperature flexibility. 
    • Facilitates product development, quality control, laboratory evaluation, procurement specifications, and product performance verification. 
    • Helps laboratories compare coating performance against the requirements specified by ASTM D6083/D6083M.

    Which Materials Can Be Tested Under ASTM D6083/D6083M?

    ASTM D6083/D6083M is intended for liquid-applied, water-dispersed acrylic latex elastomeric protective roof coatings. These coatings are supplied in liquid form and contain a water-based acrylic latex elastomeric emulsion polymer together with pigments and other additives.

    Why is ASTM D6083/D6083M important? 

    ASTM D6083/D6083M is important because the performance of an acrylic roof coating depends on more than its appearance or liquid consistency. The specification is based on both the material as supplied and the properties of the cured film that will form the protective coating function.

    ASTM D6083/D6083M Equipment and Sample Preparation Guide 

    The equipment used is dependent on the property being measured and the ASTM test method indicated by the specification. Skilled personnel prepare representative liquid coating samples and cured film samples, maintain the conditioning environment, and carry out physical and performance tests using calibrated measurement equipment.

    Read more

    Sample and Specimen DetailsTechnicians use representative samples of liquid-applied acrylic latex elastomeric protective roof coating. Samples should represent the material supplied for evaluation and should be properly identified before laboratory testing.
    Sample PreparationAnalysts thoroughly prepare the liquid coating according to the applicable referenced procedure and produce cured-film specimens when required. Personnel control film preparation, curing, conditioning, and specimen handling to obtain representative test specimens.
    Specimen DimensionSpecimen dimensions are dependent on the individual property being evaluated and the applicable ASTM-referenced test method.
    InstrumentationEquipment may include viscosity-measuring equipment, balances, volume or density measurement equipment, tensile-testing machines, permeance-testing apparatus, adhesion equipment, tear-strength equipment, accelerated-weathering equipment, low-temperature flexibility apparatus, and other instruments specified by the applicable referenced methods.

    Testing Procedures and Requirements for ASTM D6083/D6083M

    ASTM D6083/D6083M assesses the coating both as a liquid and in cured film. Technicians and analysts use the individual ASTM test methods referenced by the specification to determine the required physical properties. Other reference ASTM documents include D16, D471, D522, D624, D903, D1079, D1644, D1653, D2196, D2370, D2697, and D4798. The complete procedure for ASTM D6083 is given as:

    Read more

    Sample Identification and Liquid Coating EvaluationTechnicians identify the acrylic roof coating, record the relevant sample information, and ensure that the laboratory sample is representative of the material being evaluated. Analysts evaluate the liquid material for the properties required by the specification, including viscosity and volume and weight of solids.
    Film Preparation and Initial Mechanical PropertiesThe coating is prepared as a cured film using the applicable specimen-preparation procedure for the property being evaluated. Skilled personnel evaluate initial elongation at break and initial tensile strength at maximum stress using the applicable referenced ASTM methods.
    Accelerated Weathering and Post-Weathering PropertiesCured-film specimens are subjected to the applicable accelerated-weathering procedure before evaluation of properties specified after weathering. Analysts evaluate properties such as final elongation at break and low-temperature flexibility after the applicable accelerated-weathering exposure.
    Moisture Performance, Adhesion, and Tear ResistanceTechnicians evaluate performance and swelling according to the applicable referenced ASTM procedures. Personnel evaluate adhesion and tear resistance using the corresponding referenced ASTM methods.
    Fungi Resistance and Conformance EvaluationThe cured coating is evaluated for fungal resistance according to the applicable referenced procedure. Laboratories compare the measured properties with the applicable requirements of ASTM D6083/D6083M and document the results.

    ASTM D6083/D6083M Testing Process and Data Collection 

    The ASTM D6083/D6083M evaluation begins with representative sampling of the liquid acrylic roof coating. Technicians first identify the material supplied as a liquid by applying the appropriate requirements. Cured-film specimens are then prepared for the required physical and performance evaluations. Analysts take measurements according to the applicable ASTM test methods and record details of specimen preparation, conditioning, test conditions, measured values, and observations. Properties evaluated can include mechanical performance, permeance, water swelling, adhesion, fungi resistance, tear resistance, and low-temperature flexibility following accelerated weathering. Collected data are then compared to the requirements of applicable specifications.

     This image shows a viscosity meter used to determine the viscosity of liquid as per ASTM D6083/D6083M.
    ASTM D6083/D6083M Testing Procedure Using Viscosity Meter 

    Common Challenges and Troubleshooting 

    Representative sampling, consistent film preparation, proper conditioning, and correct use of equipment used with each referenced test method are critical to obtain reliable ASTM D6083/D6083M results. Measured properties may also be different as a result of different ways in which the coating is prepared, the thickness of the film, the curing process, the handling of the specimens, or the environmental conditioning. Technicians are responsible for verifying the calibration, adhering to appropriate referenced ASTM practices, avoiding contamination, maintaining controlled conditioning conditions, and reporting any abnormal specimen behavior and/or test observations.

    ASTM D6083/D6083M Analysis Results and Interpretation

    The liquid coating properties and cured-film performance requirements are both considered when interpreting results of ASTM D6083/D6083M in the laboratories. This specification refers to several evaluations of physical properties, each of which should be accompanied by the ASTM test method and requirement for that property.

    Read more

    • Laboratories report viscosity, solids content, tensile and elongation measurements, permeance, water swelling, adhesion, tear resistance, and other applicable values using the selected SI or inch-pound system independently. 
    • The primary results describe the liquid coating characteristics and the physical performance of the cured film, including mechanical, moisture, adhesion, weathering, biological, and low-temperature properties. 
    • Analysts document specimen preparation, film condition, accelerated-weathering exposure, conditioning, test configuration, and relevant visual observations.
    • Each result is compared with the corresponding requirement of ASTM D6083/D6083M and the applicable referenced ASTM test method.

    Link to ASTM D6038

    FAQ

    What does ASTM D6083/D6083M cover?
    It applies to liquid-applied, water-dispersed acrylic latex elastomeric protective roof coatings and sets requirements for physical properties of selected liquid and cured film.
    The specification covers water-dispersed acrylic latex elastomeric protective roof coatings. The coating is based on a water-based acrylic latex elastomeric emulsion polymer with pigments and other additives.
    The specification includes liquid-property requirements relating to viscosity and volume and weight of solids.

    Updated on October 8, 2026

    Davis Scott
    About Author
    Davis Scott is an Electrical and Electronics Engineer specializing in multidisciplinary validation, quality assurance, and comprehensive electro-mechanical testing.
    Know More
    Testimonials
    Real results
    Engineers trust us with what matters most
    Why Choose Matestlab?
    Matestlab is a unified testing services partner based in the USA. Matestlab offers raw material and product testing services through accredited, expert laboratories primarily based in the USA. Matestlab supports physical, thermal, chemical, electrical, mechanical, environmental, and characterization testing needs through its global network of 2200+ accredited testing laboratories. Matestlab's in-house materials science experts curate and design comprehensive testing programs matched to the sample material and specific testing need, with regulatory requirements and confidentiality in mind.

    If you are looking for a managed and trusted testing partner to achieve your research goals, feel free to schedule a meeting with us or send us a request at connect@matestlabs.com to learn more about our services. For a quick quote, call us at (302)244-7710. We are happy to serve you.
    Start Your Testing
    Project Today
    Define your requirements and get access to
    specialized laboratories ready to deliver results
    Partners with us
    Clients
    Vendors
    Process for testing
    • STEP 01

      You share your testing requirements

    • STEP 02

      You share your sample(s)

    • STEP 03

      We deliver your test reports

    Get your testing done

    Let us know your testing requirements and we will be right back with a solution.

      Let us root for each other. Collaborate to grow, expand, and accelerate our businesses.

      Partner with us