ASTM A937 provides a method for investigation of interlaminar resistance of electrically insulating coatings applied to adjacent laminations of flat-rolled electrical steels under specified conditions of voltage, pressure, and temperature. The method shows the effectiveness of coatings on electrical sheet steel in reducing interlaminar losses in electrical machinery, and it directly measures interlaminar resistance in units of resistance (kω). The method is especially useful for electrical steels with inorganic insulating coatings with surface insulation resistivities greater than 0.3 kω · cm² (30 kω·mm²) for the two-surface tester equipment used in Test Method A717; the method may be extended to other ranges of insulation resistivity that the equipment can test.
The scope of ASTM A937 includes:
- Material type: Flat-rolled electrical steel laminations, having an electrically insulating coating, especially inorganic coating.
- Purpose: To assess interlaminar resistance and test the effectiveness of the coating for reducing interlaminar losses.
- Properties measured: Interlaminar resistance between two adjacent test surfaces coated, in kΩ.
- Method: Two-surface tester, where the voltage, pressure, and temperature are controlled between two coated laminates.
- Result: The values of resistance are measured directly; the maximum measurable resistance is determined by the current setting used for measurement.
- Test Limitations: Results differ from those obtained by Test Method A717/A717M and are not directly comparable.
- Environmental conditions: The test is conducted under the predetermined voltage, pressure, and temperature conditions as specified by the method.
- Applications: Quality control of insulating coating application and evaluation of electrical steel used for transformers and motors.
What are the Uses of ASTM A937 Testing?
Manufacturers use ASTM A937 to assess interlaminar resistance of insulating coatings in a consistent manner, and engineers use the test to ensure the function of a coating for use on electrical machinery. This standard-
- Measures the interlaminar resistance between two adjacent coated electrical steel laminations.
- Assists in quality control for use of insulating coatings.
- Helps indicate the effectiveness of surface coatings for limiting interlaminar losses.
- Helps test the electrical steels coated with inorganic insulating coatings.
- Performs with insulation resistivities greater than those in Test Method A717.
- Helps compare coating performance between several laminations of the same lot.
What Materials Can Be Tested Under ASTM A937?
ASTM A937 applies mainly to flat-rolled electrical steel coated with electrically insulating coatings, and it is particularly useful for, but not limited to, steels coated with inorganic insulating coatings. The common application is in electrical sheet steels, which are used in electrical machines such as transformers, motors, etc., where reducing interlaminar losses is significant. Laboratories sample laminations from the same batch of electrical steel and test the uniformity of the coating throughout the steel.
Why is ASTM A937 Important?
The ASTM A937 standard helps manufacturers ensure that the quality of the coating is consistent, which ensures that the electrical steel used in the manufacture of transformers and motors works efficiently and does not lead to excessive core losses during operation. The interlaminar resistance is directly proportional to the interlaminar eddy current resistance of the insulating coating of an electrical machine. The thickness of the coating varies throughout the surface of the electrical steel, so further readings may be taken by using different contact positions, or may be necessary on several laminations from the same lot to get a representative thickness reading.