ASTM F138 Standard Specification for Wrought 18 Chromium-14 Nickel-2.5 Molybdenum Stainless Steel Bar and Wire for Surgical Implants (UNS S31673)
What is ASTM F138?
ASTM F138 is a standard specification that covers the requirements for wrought stainless steel bars and wires used in the manufacture of surgical implants. The specification helps manufacturers evaluate the material properties and quality of stainless steel intended for surgical implant applications. During production and testing, personnel examine the material composition, mechanical properties, dimensions, and metallurgical characteristics to verify compliance with the applicable requirements. Engineers use the test results and material records to assess whether the stainless steel meets the specified requirements for implant manufacturing. This specification supports material quality assessment, manufacturing consistency, and the selection of suitable stainless steel for surgical implant applications.
Get Reliable ASTM F138 Testing for Effective Surgical Implant Material Evaluation
Reliable ASTM F138 testing helps manufacturers evaluate the quality and suitability of wrought stainless steel bars and wires for surgical implants. The specification establishes requirements for chemical composition, mechanical properties, and relevant material characteristics. Testing personnel perform the required tests and compare the results with the specified criteria to verify material compliance. This process supports consistent material quality and reliable implant manufacturing.
What is the Scope of ASTM F138?
ASTM F138 is a standard specification that establishes requirements for wrought 18 chromium-14 nickel-2.5 molybdenum stainless steel bars and wires used to manufacture surgical implants. The specification covers material characteristics and requirements that help manufacturers assess the suitability of stainless steel for implant applications. Testing personnel examine the material’s chemical composition, mechanical properties, dimensions, and other specified characteristics to verify compliance with the applicable requirements.
Material type: Wrought 18 chromium-14 nickel-2.5 molybdenum stainless steel bars and wires (UNS S31673) intended for surgical implant manufacturing.
Purpose: Establish requirements for stainless steel used in surgical implants and help manufacturers verify material quality.
Properties evaluated: Chemical composition, mechanical properties, and other material characteristics specified by the standard.
Analysis method: Examine the material, perform the applicable chemical and mechanical tests, and compare the results with the requirements of the specification.
Result: Determine whether the stainless steel meets the applicable requirements for surgical implant materials.
Analysis limitations: Interpret the results in relation to the specified material requirements and testing conditions. Compliance with ASTM F138 alone does not establish the safety or suitability of a finished implant for every clinical application.
Methodology: Identify the material, prepare test specimens, perform the required examinations and tests, evaluate the results against the specification, and document the findings.
Applications: Support material quality assessment, manufacturing consistency, quality control, and the selection of stainless steel bars and wires for surgical implant production.
What are the Uses of ASTM F138 Testing?
ASTM F138 provides requirements for wrought stainless steel bars and wires used in surgical implant manufacturing. The standard specification:
Establishes requirements for the chemical composition of stainless steel used in surgical implants.
Helps manufacturers evaluate the mechanical properties of stainless steel bars and wires.
Supports quality-control activities during implant material production.
Allows manufacturers to verify material compliance with the specified requirements.
Helps engineers assess the suitability of stainless steel for surgical implant manufacturing.
Supports consistent material quality across production batches.
Provides a basis for evaluating material characteristics through the required tests and examinations.
Supports material selection and quality assurance in the medical device industry.
Helps manufacturers document and verify material properties for surgical implant applications.
What Materials Can Be Tested Under ASTM F138?
ASTM F138 covers wrought 18 chromium-14 nickel-2.5 molybdenum stainless steel bars and wires (UNS S31673) intended for surgical implant manufacturing. Manufacturers use this material to produce implant components that require specific chemical and mechanical properties. The specification focuses on the applicable wrought bar and wire forms rather than all types of stainless steel. Testing personnel evaluate representative specimens and compare their chemical composition, mechanical properties, and other specified characteristics with the applicable requirements.
Why is ASTM F138 Important?
ASTM F138 establishes requirements for evaluating wrought stainless steel bars and wires used in surgical implant manufacturing. These requirements help manufacturers assess the material’s chemical composition, mechanical properties, and conformity with specified criteria, allowing them to verify material quality and consistency. The results of ASTM F138 evaluation therefore support material selection, quality control, production consistency, and the assessment of stainless steel materials for surgical implant applications.
ASTM F138 Equipment and Sample Preparation Guide
ASTM F138 requires suitable analytical instruments and mechanical testing equipment to evaluate wrought stainless steel bars and wires intended for surgical implant manufacturing. The equipment should support the assessment of chemical composition, tensile properties, and other specified material characteristics to help determine whether the stainless steel meets the applicable specification requirements.
Technicians select representative specimens of wrought stainless steel bars or wires to evaluate compliance with ASTM F138 requirements. The specimens must represent the material under examination and meet the applicable sampling requirements.
Specimen preparation
Technicians prepare the test specimens according to the applicable requirements for chemical analysis, mechanical testing, and other specified examinations. They ensure that specimen preparation does not introduce contamination or affect the test results.
Specimen Dimensions
Technicians measure and record the dimensions of the stainless steel bars or wires and prepare specimens that meet the requirements of the applicable tests. Accurate measurements help technicians evaluate dimensional compliance and maintain consistent testing conditions.
Instrumentation
The testing setup may include chemical analysis instruments, a tensile testing machine, dimensional measuring tools, and equipment for other required examinations. Technicians verify the equipment’s calibration and operating condition before testing to obtain reliable measurements.
Testing Procedures and Requirements for ASTM F138
ASTM F138 establishes requirements for wrought stainless steel bars and wires intended for surgical implant manufacturing. Testing personnel examine the material, perform the applicable tests, and compare the results with the specification’s requirements. The testing procedure comprises:
Technicians select wrought stainless steel bars or wires intended for surgical implant manufacturing and verify the material identification and applicable grade requirements.
Specimen Preparation
Technicians prepare representative specimens according to the requirements of the applicable chemical, mechanical, and other specified tests. They handle the specimens carefully to prevent contamination or damage.
Chemical Composition Analysis
Technicians analyze the stainless steel’s chemical composition using suitable analytical equipment and compare the measured values with the chemical composition requirements specified by ASTM F138.
Mechanical Testing
Technicians conduct the required mechanical tests using suitable testing equipment and evaluate the results against the applicable mechanical property requirements.
Dimensional and Material Examination
Technicians measure the material dimensions and perform other examinations required by the specification. They compare the observations and measurements with the applicable acceptance criteria.
Evaluation of Test Results
Technicians review the chemical, mechanical, dimensional, and other required results to determine whether the tested material meets the applicable ASTM F138 requirements.
Result Reporting
Technicians document the material identification, specimen details, testing methods, measured results, and compliance findings in the test report.
ASTM F138 Testing Process and Data Collection
Testing personnel begin the ASTM F138 evaluation by identifying the stainless steel bars or wires and preparing the required test specimens. They inspect the testing equipment, verify its calibration, and select the appropriate procedures for chemical analysis, mechanical testing, and other required examinations. Personnel conduct the specified tests and compare the measured properties with the applicable requirements of the specification. They record the material grade, specimen identification, dimensions, chemical composition, mechanical properties, testing conditions, and measured results. After collecting the test data, personnel evaluate whether the stainless steel meets the applicable ASTM F138 requirements. Finally, they prepare a report that identifies the material and specimens, describes the testing procedures, presents the results, and documents any unusual observations or deviations from the specified requirements.
ASTM F138 Testing of a Stainless Steel Bar Specimen
Common Challenges and Troubleshooting
Accurate specimen preparation, properly calibrated equipment, suitable testing procedures, and reliable measurements are essential for obtaining dependable ASTM F138 results. Incorrect specimen dimensions, contamination, equipment calibration errors, or inconsistent testing procedures can affect the results and reduce measurement reliability. Testing personnel should inspect the specimens, verify the equipment calibration, confirm the applicable testing requirements, and follow the specified procedures. They should also review the chemical composition and mechanical test results, check the test records, and document any unusual observations or deviations from the applicable requirements.
ASTM F138 Analysis Results and Interpretation
The test report presents the measured chemical composition, mechanical properties, and other specified characteristics of the wrought stainless steel bars and wires obtained through the required examinations. The analyst interprets the results by considering the material grade, specimen characteristics, testing conditions, and applicable requirements of the specification.
Testing personnel record the chemical composition of the stainless steel to evaluate its conformity with the applicable requirements of ASTM F138.
Analysts review the mechanical test results and compare the measured properties with the specification’s acceptance criteria.
Technicians document the material identification, stainless steel grade, specimen dimensions, and preparation details to maintain accurate traceability.
Analysts record the testing conditions, equipment information, measurement parameters, and relevant instrument details used during the evaluation.
Analysts examine the test data to identify unexpected measurements, inconsistencies, or deviations from the applicable specification requirements.
Engineers can compare material properties across different specimens or production batches to assess consistency and support quality-control activities.
Overall, ASTM F138 provides requirements for wrought stainless steel bars and wires (UNS S31673) intended for surgical implant manufacturing. The evaluation results can support material characterization, quality control, production consistency, and material selection. However, compliance with ASTM F138 alone does not establish the safety or clinical suitability of a finished implant for every application.
ASTM F138 establishes requirements for wrought 18 chromium-14 nickel-2.5 molybdenum stainless steel bars and wires (UNS S31673) used in surgical implant manufacturing. Manufacturers use the specification to evaluate material compliance with the applicable requirements.
Why do testing personnel evaluate stainless steel under ASTM F138?
Testing personnel evaluate stainless steel to verify its compliance with the specified chemical composition, mechanical properties, and other applicable material requirements. The results help manufacturers assess material quality and maintain production consistency.
What results do personnel collect during ASTM F138 testing?
Personnel record material identification, specimen dimensions, chemical composition, mechanical test results, testing conditions, and other required observations. They use these findings to determine whether the material meets the applicable requirements of the specification.
Davis Scott is an Electrical and Electronics Engineer specializing in multidisciplinary validation, quality assurance, and comprehensive electro-mechanical testing. Know More
Testimonials
Real results
Engineers trust us with what matters most
“We had a great experience working with this company for our ASTM E84 testing. They were the first company to respond to our inquiry within just a few minutes of submitting it. From start to finish, the communication was excellent, and the entire process was swift, straightforward, and hassle-free.”
Ivars FancyWalls
United States
“Very good communication, testing associates were very patient with delays on our end. Reasonable turnaround time for results and nicely detailed report. Analysts were also quick to answer any follow-up questions. Happy with results.”
Skye Henderson
United States
“Matestlab connected us with an accredited lab within days, cutting weeks off our product validation timeline.”
Rebecca Kozodoy-Pins
United States
Why Choose Matestlab?
Matestlab is a unified testing services partner based in the USA. Matestlab offers raw material and product testing services through accredited, expert laboratories primarily based in the USA. Matestlab supports physical, thermal, chemical, electrical, mechanical, environmental, and characterization testing needs through its global network of 2200+ accredited testing laboratories. Matestlab's in-house materials science experts curate and design comprehensive testing programs matched to the sample material and specific testing need, with regulatory requirements and confidentiality in mind.
If you are looking for a managed and trusted testing partner to achieve your research goals, feel free to schedule a meeting with us or send us a request at connect@matestlabs.com to learn more about our services. For a quick quote, call us at (302)244-7710. We are happy to serve you.
Start Your Testing Project Today
Define your requirements and get access to specialized laboratories ready to deliver results