ASTM E507 Standard Test Method for Determination of Aluminum in Iron Ores by Flame Atomic Absorption Spectrometry

    What is ASTM E507?

    ASTM E507 is a standard test method for the determination of aluminum in iron ores, concentrates, and agglomerates using Flame Atomic Absorption Spectrometry (F-AAS). Aluminum is determined in such materials in a mass fraction (%) range from 0.1 to 5. The values are stated in SI units as they are considered standard units.

    What is the Scope of ASTM E507?

    ASTM E507 is used to determine aluminum content in iron ores using the F-AAS technique. It is considered a reference method for compliance with compositional specifications for impurity content. 

    Read more

    • Target Material: Iron ores, concentrates, and agglomerates.
    • Target Element: Aluminum (Al).
    • Concentration Range: Mass fraction from 0.1% to 5%.
    • Technique Used: Flame atomic absorption spectrometry (F-AAS).
    • Purpose of the test: Acts as a referee method for compliance with compositional specifications regarding impurity content.
    • Safety and Units: Uses standard SI units and requires users to establish appropriate health, safety, and environmental practices.

    ASTM E507 Testing Procedure and Requirements

    The analytical sample shall be pulverized to pass a 150-μm sieve. The sample is first mixed in HCl and HNO3. Then it is evaporated and dehydrated so that any residue can be easily filtered, and then it is added into the main solution. The main solution is aspirated by the flame of a nitrous oxide-acetylene burner. The absorbed energy at the resonance line of the spectrum of aluminum is measured by atomic absorption spectrometry and compared with that of the calibration solutions.

    Read more

    This image shows Flame Atomic Absorption Spectrometry (F-AAS) Lab Set-up
    Flame Atomic Absorption Spectrometry (F-AAS) Lab Set-up

    ASTM E507 Result Analysis and Interpretation

    The test results report aluminum in iron ores, concentrates, and agglomerates in the mass fraction (%) range from 0.1 to 5.

    Read more

    Updated on August 29, 2026

    Suyog Kamble
    About Author
    Suyog Kamble is an Operations Associate at Matestlab Inc. Suyog holds a postgraduate degree in organic chemistry and is trained in material science topics.
    Know More
    Testimonials
    Real results
    Engineers trust us with what matters most
    Start Your Testing
    Project Today
    Define your requirements and get access to
    specialized laboratories ready to deliver results
    Partners with us
    Clients
    Vendors
    Process for testing
    • STEP 01

      You share your testing requirements

    • STEP 02

      You share your sample(s)

    • STEP 03

      We deliver your test reports

    Get your testing done

    Let us know your testing requirements and we will be right back with a solution.

      Let us root for each other. Collaborate to grow, expand, and accelerate our businesses.

      Partner with us

        Discover more from Matestlab

        Subscribe now to keep reading and get access to the full archive.

        Continue reading