ASTM E376 Coating Thickness Measurement Using Electromagnetic Methods

    What is ASTM E376?

    ASTM E376 is a standard practice for the nondestructive measurement of coating thickness with magnetic-field and eddy current gauges, applied to a metal substrate that conducts electricity. The substrate is either ferrous or nonferrous, and the coating or plating being measured is either electrically conducting or insulating, either ferrous or nonferrous; hence, one practice covers measurement of paint on steel, paint on aluminum, and a variety of plated coatings. Magnetic gauges measure either the force of attraction between a magnet and the coating or substrate or the reluctance of a magnetic circuit including the coating and the substrate, an approach that is suitable for a nonmagnetic coating on a magnetic substrate, and in some cases, for nickel coatings on both magnetic and nonmagnetic substrates. ASTM E376 (Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy Current (Electromagnetic) Testing Methods) treats accuracy with care, since the instrument, the calibration foils, and the operating conditions all shape the result, and measurements made under the practice comply with ISO 2178 as printed in 1982. Under ideal conditions, the practice supports a result within ±10 % of true thickness or ±2.5 µm, whichever is greater, though part curvature, magnetic permeability, electrical conductivity, and surface roughness all pull a real reading away from that best case.

    Read more

    Get Certified ASTM E376 for Reliable Coating Thickness Measurement

    ASTM E376 is used by coaters, plating shops, and inspection personnel to ensure that a coating is deposited within the thickness required by a specification, while not damaging the part. Maintaining consistent gauge technique ensures that measurements are consistent across shifts, locations, and suppliers and reduces rework and re-acceptance of lots. Matestlab is offering calibrated thickness gauges and knowledgeable analysts to the process to measure coatings on metal substrates in accordance with ASTM E376.

    What is the Scope of the ASTM E376?

    ASTM E376 is a standard practice that defines the boundary with regard to the use of magnetic- and eddy current-type thickness gauges for the nondestructive measurement of a magnetic or eddy current type coating on an electrically conducting substrate. Neither the substrate nor the coating or plating changes from ferrous or nonferrous to electrically conducting or insulating. These gauges have more specific uses that are listed in other documents referenced by the practice points, and SI units are the standard units of measurement with parenthetical units being provided for informational purposes only.

    Read more

    The scope of ASTM E376 includes:

    • Material type: Coatings and platings, conducting or insulating, on ferrous or nonferrous metal substrates.
    • Purpose: Nondestructive measurement of coating thickness with magnetic-field and eddy current gauges.
    • Property evaluation: Coating thickness, expressed in micrometers, with inch-pound conversions given for information only.
    • Testing method: Magnetic gauges sense magnet attraction or flux-path reluctance, and eddy current gauges sense impedance changes in an inducing coil.
    • Results: Thickness readings vary by instrument, calibration foils, and operating conditions.
    • Test limitation: Most gauges suit only certain coating and substrate combinations, and eddy current gauges need a coating conductivity that differs significantly from the substrate.
    • Use conditions: Measurements under the practice comply with ISO 2178 as printed in 1982, and the gauge maker’s stated limits guide instrument selection.
    • Application: Supports paint, plating, and anodized or similar layers on steel, aluminum, and other metals in quality control and inspection.

    What are the Uses of ASTM E376 Testing?

    ASTM E376 testing helps coaters and inspectors confirm that a coating meets a thickness requirement without damaging the coated part. Quality teams also use the readings to control processes such as painting and plating before a lot moves on. This standard-

    • Measures coating thickness on ferrous and nonferrous metal substrates without damaging the part.
    • Supports quality control of paint, plating, and similar coating lines.
    • Helps select a magnetic or eddy current gauge for a given coating and substrate pair.
    • Confirms compliance with thickness requirements in product specifications.
    • Compares thickness across production lots, shifts, and suppliers.
    • Directs users to more specific test methods for particular coating types.

    Which materials can be tested under ASTM E376?

    ASTM E376 applies to coatings and platings on electrically conductive substrates, including both ferrous and nonferrous, and electrically conductive or insulating coatings. If the paint or insulating film conductivity differs from the substrate, you can use a magnetic gauge for steel and an eddy-current gauge for aluminum. If the substrate does not conduct, like plastic or wood, then it is not part of the practice; if the coating has the same electrical conductivity as the substrate, then it does not provide any information to the eddy current gauge.

    Why is ASTM E376 Important?

    Coating thickness determines a part’s finish durability, appearance, and function, so the gauge reading directly influences accept/reject decisions. Thin coatings leave the metal exposed, and thick coatings consume material and can cause adhesion and cure issues. According to ASTM E376, measurement ensures that the decisions made by coaters, inspectors, and laboratories are consistent without making any cuts into the part.

    ASTM E376 Equipment and Sample Preparation Guide

    ASTM D7091 specifies testing equipment and procedures for non-destructive measurement of dry film thickness of non-magnetic coatings on magnetic substrates and non-conductive coatings on non-magnetic substrates. Technicians prepare test specimens and perform the required measurements. 

    Read more

    Specimen Details Technicians test coated metallic and non-magnetic component samples, prepared for controlled non-destructive thickness evaluation. 
    Specimen Preparation Technicians clean and examine representative coated surfaces to ensure they are free of dirt, grease, or loose debris that could affect probe contact. 
    Instrumentation Technicians use magnetic-field thickness gauges, permanent magnet instruments, electromagnetic eddy current meters, certified calibration standards, and reference thickness shims. 

    Testing Procedures and Requirements for ASTM E376

    Coating thickness measurement follows a specific sequence, from gauge selection to recording readings. Technicians confirm the coating and substrate combination and the gauge limits before measurement begins. Other reference documents include ASTM D7091 for nondestructive dry film thickness of nonmagnetic coatings on ferrous and nonferrous metals, B244 for eddy current measurement of anodic and other nonconductive coatings on nonmagnetic basis metals, B499 for nonmagnetic coatings on magnetic basis metals, and B530 for electrodeposited nickel coatings. The ASTM E376 procedure comprises the following steps-

    Read more

    Gauge SelectionTechnicians match a magnetic or eddy current gauge to the coating and substrate pair and check the gauge maker’s limits.
    CalibrationThe technician sets up the gauge on calibration foils of known thickness and confirms the reading on the bare substrate.
    MeasurementThe technician places the probe steadily on the coated surface and reads the thickness value, noting part curvature and surface roughness at the spot.
    Interference ReviewAnalysts note part curvature, magnetic permeability, electrical conductivity, and surface roughness that pull a reading away from true thickness.
    Result ReportingLaboratories report thickness in micrometres with reference to ASTM E376, the gauge type, and the calibration used.

    ASTM E376 Testing Process and Data Collection

    A technician reviews the coating and substrate combination, then selects a magnetic gauge for a nonmagnetic coating on a magnetic substrate or an eddy current gauge where the conductivity of the coating and substrate differs. The technician calibrates on foils of known thickness, confirms the reading on the bare substrate, and places the probe on the coated surface. Repeated readings across the part show how thickness varies from spot to spot. Analysts note curvature, roughness, and the gauge and calibration used, then compile the readings into the part’s inspection record.

     The image shows a coating thickness gauge probe on a coated steel panel during thickness measurement according to ASTM E376.
     ASTM E376 Coating Thickness Measurement on a Coated Steel Panel

    Common Challenges and Troubleshooting

    Choosing the wrong gauge is a common mistake. Most thickness gauges only work for specific combinations of coatings and base materials. For example, an eddy current gauge won’t read much if the coating’s electrical conductivity is similar to the base material. Other factors can also mess with readings. Things like the curve of the part, how magnetic it is, its electrical conductivity, and how rough the surface is can all throw off the measurement of the true thickness. To avoid these problems, technicians should check the coating and base material combination before selecting a gauge. They should also calibrate the gauge using foil pieces that are close to the expected thickness. When possible, it’s best to take measurements on a flat, clean surface.

    ASTM E376 Analysis Results and Interpretation

    A reading under ASTM E376 comes as a single thickness value in micrometers, and its meaning depends on the gauge type, calibration, and the coating-and-substrate pair behind it. Analysts report the value together with the tolerance the practice supports, since a gauge reading estimates true thickness and does not measure it exactly. Magnetic gauges apply where a nonmagnetic coating sits on a magnetic substrate, such as paint on steel, while eddy current gauges apply where the coating conductivity differs significantly from the substrate, such as paint on aluminum. Every reading also carries the influence of part curvature, magnetic permeability, electrical conductivity, and surface roughness, so a laboratory records those conditions beside the number. The bullets below turn the tolerance rule into working figures.

    Read more

    • Analysts specify each measurement with its tolerance; under ideal conditions, the practice establishes a determination within ±10% of true thickness or within ±2.5 µm (±0.0001 in.), whichever is greater.
    • Engineers identify the crossover where the two limits meet: 10% of 25 µm equals 2.5 µm, so below 25 µm the ±2.5 µm floor governs and above 25 µm the ±10% term governs.
    • Technicians apply the rule to a 20 µm coating, where 10% equals 2.0 µm, so the ±2.5 µm floor governs, and the reading falls in a band of 17.5 to 22.5 µm.
    • Technicians apply the rule to a 60 µm coating, where 10% equals 6.0 µm, so the ±10% term governs and the reading falls in a band of 54 to 66 µm.
    • Analysts convert between unit systems when a specification uses mils, so a 2.0 mil coating reads as 50.8 µm, because SI units stand as the standard and 1 mil equals 25.4 µm.
    • Laboratories log the interferences, gauge, foils, and calibration used with every reading, so a reviewer can trace each thickness value back to the conditions behind it.

    Link to ASTM E376

    FAQ

    What does ASTM E376 measure?
    ASTM E376 measures the thickness of a coating on an electrically conducting metal substrate, reported in micrometers, using either a magnetic gauge or an eddy current gauge.
    ASTM E376 matters for coating quality control because it gives a nondestructive thickness reading that feeds accept or reject decisions without cutting into the coated part.
    Under ideal conditions, a reading falls within ±10 % of true thickness or within ±2.5 µm (±0.0001 in.), whichever is greater. Part curvature, magnetic permeability, electrical conductivity, and surface roughness pull a real reading away from that best case.

    Updated on October 12, 2026

    Davis Scott
    About Author
    Davis Scott is an Electrical and Electronics Engineer specializing in multidisciplinary validation, quality assurance, and comprehensive electro-mechanical testing.
    Know More
    Testimonials
    Real results
    Engineers trust us with what matters most
    Why Choose Matestlab?
    Matestlab is a unified testing services partner based in the USA. Matestlab offers raw material and product testing services through accredited, expert laboratories primarily based in the USA. Matestlab supports physical, thermal, chemical, electrical, mechanical, environmental, and characterization testing needs through its global network of 2200+ accredited testing laboratories. Matestlab's in-house materials science experts curate and design comprehensive testing programs matched to the sample material and specific testing need, with regulatory requirements and confidentiality in mind.

    If you are looking for a managed and trusted testing partner to achieve your research goals, feel free to schedule a meeting with us or send us a request at connect@matestlabs.com to learn more about our services. For a quick quote, call us at (302)244-7710. We are happy to serve you.
    Start Your Testing
    Project Today
    Define your requirements and get access to
    specialized laboratories ready to deliver results
    Partners with us
    Clients
    Vendors
    Process for testing
    • STEP 01

      You share your testing requirements

    • STEP 02

      You share your sample(s)

    • STEP 03

      We deliver your test reports

    Get your testing done

    Let us know your testing requirements and we will be right back with a solution.

      Let us root for each other. Collaborate to grow, expand, and accelerate our businesses.

      Partner with us