ASTM E37 Standard Test Methods for Chemical Analysis of Pig Lead

    What is ASTM E37? 

    ASTM E37 is a historical ASTM standard that provides test methods for chemically analyzing pig lead. This edition covers pig lead compositions containing 99.5% to 99.99% lead and specifies concentration ranges for several alloying and impurity elements. The listed ranges include antimony from 0.001 to 0.02%, arsenic from 0.0005 to 0.02%, bismuth from 0.002 to 0.2%, copper from 0.001 to 0.1%, iron from 0.0005 to 0.005%, silver from 0.001 to 0.03%, tin from 0.001 to 0.02%, and zinc from 0.001 to 0.005%. Two main techniques are used in the analytical procedures of E37. Atomic absorption spectrophotometry is used after chemical dissolution and separation of lead to determine copper, bismuth, silver, and zinc. Antimony is determined using a Rhodamine-B photometric method. ASTM E37 (Standard Test Methods for Chemical Analysis of Pig Lead) also establishes proper laboratory sampling, significant digits, apparatus, reagents, safety, and interlaboratory evaluation practices.

    Read more

    Get Certified ASTM E37 Testing for Reliable Pig Lead Chemical Composition Evaluation 

    Qualified analytical laboratories can use the ASTM E37 procedures to determine specified elemental constituents in pig lead. Analysts are trained to prepare representative samples, dissolve and separate the samples chemically, and set suitable conditions for calibration. Atomic absorption and photometric measurements provide quantitative analytical data for the applicable elements. The resulting composition data can support comparison with applicable pig-lead compositional specifications.

    What is the scope of ASTM E37? 

    ASTM E37 covers chemical analysis of pig lead having compositions within specified concentration ranges. The standard includes antimony, arsenic, bismuth, copper, iron, lead, silver, tin, zinc, and the analytical methods are specifically described for antimony and for copper, bismuth, silver, and zinc.

    Read more

    The scope of ASTM E37 includes:

    • Material: Pig lead with the chemical-composition ranges specified by the standard. 
    • Objective: Determine specified elemental constituents in pig lead for chemical-composition evaluation. 
    • Property measurement: Analysis of antimony, copper, bismuth, silver, and zinc, and ranges for arsenic, iron, lead, and tin. 
    • Method: Rhodamine-B photometry is used to analyze antimony, and atomic absorption is used to analyze copper, bismuth, silver, and zinc. 
    • Result: Laboratory results provide quantitative elemental concentrations, usually expressed as a percentage, to compare with relevant compositional standards. 
    • Test limitations: The individual analytical procedures apply only to their specified elements and concentration ranges. The standard does not specify one type of analysis for each of the elements in the scope. 
    • Environmental conditions: An analytical laboratory equipped for testing, conditions of the instruments, and the use of appropriate reagents and safety measures. 
    • Applications: The methods are applicable for chemical-composition testing and evaluation of pig lead against applicable material specifications.

    What are the uses of ASTM E37 testing? 

    ASTM E37 primarily supports chemical-composition testing of pig lead. The standard specifies methods primarily for chemical analysis of metals and alloys to determine conformance to compositional specifications. This standard-

    • Determines antimony using a Rhodamine-B photometric procedure. 
    • Determines copper, bismuth, silver, and zinc using atomic absorption. 
    • Supports compositional evaluation of pig lead. 
    • Provides concentration ranges within which the analytical methods apply. 
    • Sets calibration and photometric specifications for the atomic absorption method. 
    • Provides a framework for chemical dissolution, separation, measurement, calculation, and reporting. 
    • Compares analytical results to relevant pig-lead specifications.

    Which Materials Can Be Tested Under ASTM E37? 

    ASTM E37 focuses specifically on pig lead and does not apply to other lead alloys or unrelated metallic materials. The scope defines pig lead comprising 99.5 to 99.99% lead and specifies ranges for antimony, arsenic, bismuth, copper, iron, silver, tin, and zinc.

    Why is ASTM E37 important? 

    The chemical composition directly influences whether refined or pig lead conforms to a specified grade or material requirement. ASTM E37 gives analysts defined analytical procedures to help them produce quantitative data from controlled calibration, chemical preparation, and instrumental measurement.

    ASTM E37 Equipment and Sample Preparation Guide 

    ASTM E37 provides analytical equipment suitable for the chemical procedure selected. Skilled personnel prepare the pig-lead sample through controlled dissolution and separation before measuring the target elements.

    Read more

    Sample and Specimen DetailsAnalysts use representative pig-lead material and identify the elements and expected concentration ranges before selecting the applicable procedure.
    Sample PreparationTechnicians dissolve the sample using the specified acid treatment. For the atomic absorption procedure, this edition uses a 10.0-g sample, weighed to the nearest 10 mg, followed by dissolution in nitric-perchloric acid and precipitation of lead chloride with hydrochloric acid.
    Specimen DimensionThe standard does not specify a universal physical specimen dimension because chemical analysis uses a weighed sample rather than a shaped test specimen.
    InstrumentationEquipment includes an atomic absorption spectrophotometer with hollow-cathode lamps, air-acetylene flame equipment, analytical balance, beakers, Erlenmeyer flasks, volumetric flasks, pipets, heating equipment, and suitable photometric equipment.

    Testing Procedures and Requirements for ASTM E37 

    ASTM E37 contains separate analytical procedures. The atomic absorption method dissolves pig lead, removes lead as lead chloride, and measures the target elements in the resulting solution. The standard sets calibration and instrument performance checks before analytical measurement. Other reference ASTM documents include B29, E29, E50, E60, E135, E173, and E1601. The complete procedure for ASTM E37 is given below:

    Read more

    Sample Selection and DissolutionPersonnel obtain a representative pig-lead sample according to the applicable sampling procedure. For the atomic absorption procedure, technicians transfer a 10.0-g sample to a 300-mL Erlenmeyer flask, add nitric and perchloric acids, and heat until dissolution is complete.
    Lead SeparationAnalysts evaporate the solution to strong perchloric-acid fumes, cool it, add water and hydrochloric acid, and precipitate lead chloride.
    Calibration PreparationPersonnel prepare dilute standard solutions and 5 calibration solutions for each element. The calibration solutions use increasing aliquots of the appropriate dilute standard and match the acid concentrations of the test solution.
    Instrument AdjustmentAnalysts adjust the atomic absorption spectrophotometer, optimize the wavelength, allow thermal equilibrium, and optimize fuel, air, and burner settings while aspirating the highest calibration solution.
    Instrument Performance Check and Photometric MeasurementPersonnel verify minimum response, calibration-curve linearity, and stability. Technicians aspirate the test and calibration solutions, record stable responses, and repeat the measurement sequence as specified.
    Calculation and ReportingAnalysts subtract the reagent blank, prepare a calibration curve, convert net absorbance into elemental concentration, and calculate the element percentage in the sample. Laboratories report elemental concentrations, including the appropriate units and rounding procedures, along with the sample identification and analytical method and quality-control data.

    ASTM E37 Testing Process and Data Collection 

    The ASTM E37 testing process involves representative sampling, chemical dissolution/separation, calibration, instrumental measurement, calculation, and reporting. Analysts prepare five calibration solutions for the atomic absorption method and determine the concentration of the test solution based on the net absorbance. Reagent blanks and instrument stability are also considered in the standard. Its precision section reports an interlaboratory study involving seven laboratories, while the standard notes that accuracy could not be evaluated at that time because adequate certified reference materials were unavailable.

     This image shows an atomic absorption spectrophotometer used to determine chemical analysis of pig lead as per ASTM E37.
    ASTM E37 Testing Procedure Using Atomic Absorption Spectrophotometer

    Common Challenges and Troubleshooting 

    Reliable and accurate results require representative sampling, complete sample dissolution, effective lead separation, appropriate calibration solutions, stable instrument response, and careful handling of precipitates. Analysts should ensure that the calibration range matches the expected concentration and verify minimum response, curve linearity, and stability before accepting measurements. Silver requires particular attention because of its limited solubility as silver chloride; the standard notes that the silver concentration in the sample solution should remain below the applicable limit, and the sample mass may need adjustment when higher silver concentrations are expected. Analysts should also prevent precipitated lead chloride from entering the aspirator because particles can interfere with measurement.

    ASTM E37 Analysis Results and Interpretation 

    ASTM E37 produces quantitative chemical composition data for the elements covered by its analytical procedures. Analysts use photometric or atomic-absorption responses to convert them into elemental concentrations, then compare the results to the appropriate compositional specification.

    Read more

    • Laboratories report elemental concentrations, generally in percent, for the applicable analytes and use the required significant-digit and rounding practices. 
    • Technicians record the primary concentration results together with sample identification, sample mass, analytical method, calibration range, and relevant preparation details. 
    • Analysts record instrument settings, calibration results, reagent blanks, replicate tests, and observations, including precipitate behavior or stability issues. 
    • Engineers and quality personnel compare the measured composition with the applicable pig-lead specification or contractual compositional requirements rather than applying an acceptance criterion created by ASTM E37 itself.

    Link to ASTM E37

    FAQ

    What does ASTM E37 measure?
    ASTM E37 provides chemical-analysis procedures for pig lead, with specific procedures for antimony and for copper, bismuth, silver, and zinc.
    This scope identifies antimony, arsenic, bismuth, copper, iron, lead, silver, tin, and zinc in concentration ranges.
    The atomic absorption procedure determines copper, bismuth, silver, and zinc.

    Updated on September 24, 2026

    Laraib Hashmi
    About Author
    Laraib Hashmi is an aspiring research enthusiast and science content professional with a strong interdisciplinary skill set, holding a postgraduate degree in Applied Microbiology from KIIT Bhubaneshwar, Odisha.
    Know More
    Testimonials
    Real results
    Engineers trust us with what matters most
    Why Choose Matestlab?
    Matestlab is a unified testing services partner based in the USA. Matestlab offers raw material and product testing services through accredited, expert laboratories primarily based in the USA. Matestlab supports physical, thermal, chemical, electrical, mechanical, environmental, and characterization testing needs through its global network of 2200+ accredited testing laboratories. Matestlab's in-house materials science experts curate and design comprehensive testing programs matched to the sample material and specific testing need, with regulatory requirements and confidentiality in mind.

    If you are looking for a managed and trusted testing partner to achieve your research goals, feel free to schedule a meeting with us or send us a request at connect@matestlabs.com to learn more about our services. For a quick quote, call us at (302)244-7710. We are happy to serve you.
    Start Your Testing
    Project Today
    Define your requirements and get access to
    specialized laboratories ready to deliver results
    Partners with us
    Clients
    Vendors
    Process for testing
    • STEP 01

      You share your testing requirements

    • STEP 02

      You share your sample(s)

    • STEP 03

      We deliver your test reports

    Get your testing done

    Let us know your testing requirements and we will be right back with a solution.

      Let us root for each other. Collaborate to grow, expand, and accelerate our businesses.

      Partner with us