ASTM D2457 test method is used to determine specular gloss of plastic films and solid plastic materials. Specular gloss usually varies with surface smoothness and flatness. It is sometimes used for comparative measurements of these surface properties. However, gloss values for transparent films should not be compared with those for opaque films, and vice versa. ASTM D2457 test method describes procedures for the measurement of gloss of plastic films and solid plastics, both opaque and transparent. It contains five separate gloss angles: (a) 60-deg, recommended for intermediate-gloss films, (b) 20-deg, recommended for high-gloss films, (c) 45-deg, recommended for intermediate and low-gloss films, (d) 85-deg, recommended for intermediate and low gloss films, and (e) 75-deg, recommended for plastic siding and soffit.
By quantifying glossiness through the ASTM D2457 test method, manufacturers, researchers, and quality control personnel can assess the surface finish and reflective properties of plastic materials, ensuring compliance with industry requirements and enhancing product quality.
ASTM D2457 Test Procedure
| Specimen Selection | A clean plastic film or solid specimen is essential for accurate gloss measurement. It has a smooth, flat surface and is sufficiently thick for transparent or translucent materials to prevent significant light transmission during testing. |
| Test Setup and Execution | A gloss meter measures specular gloss by placing a plastic specimen on a stable surface, adjusting the angle (60 degrees), and measuring light reflection. The gloss value should be accurately and repeatably measured following ASTM D2457 standard instructions for repeatable results. |