ASTM E283 sets the test process that is used to determine the rate of air intrusion or exfiltration of a fenestration system or door. Thermal performance, indoor air quality, moisture control, and overall energy consumption are affected by the components of building envelopes. Standard manufacturers, architects, engineers, and regulatory agencies are fundamental for energy efficiency criteria and design performance requirements. Through this type of test, findings are applied to confirm product ratings, certify design specifications, and meet standards such as ASHRAE 90.1 and IECC.
ASTM E283 Test Method
| Specimen Mounting | Window, door, skylight, or curtain wall installed in a test chamber per manufacturer’s instructions. |
| Pressure Application | Specified positive or negative air pressure differences are applied across the specimen. |
| Airflow Measurement | The rate of air leakage is determined by measuring the airflow supplied to or removed from the chamber to maintain pressure. |
| Calculation | Air leakage is expressed in cubic feet per minute (cfm) per square foot of specimen area or per unit length of crack/joint. |
| Acceptance Criteria | Results are compared to allowable leakage rates defined by specifications, codes, or product standards. |