ASTM D6184 evaluates the propensity of lubricating grease to separate oil when exposed to elevated temperatures. MaTestLab is one of the best testing service providers, with the best network of testing laboratories in the USA to carry out ASTM D6184 tests for our clients. It is typically conducted at 100°C for 30 hours, although the grease standards may specify different conditions. Greases with a worked penetration greater than 220 mm ⁄10 can undergo this test.
ASTM D6184 Test Method
| Heating the Sample | The procedure involves placing the measured sample in a cone-shaped wire cloth filter and then suspending it in a beaker. The setup is heated under static conditions for the duration and temperature recommended by ASTM D6184. Unless specified otherwise in the grease specification, the sample is typically subjected to standard conditions of 100 ± 0.5°C for 30 ± 0.25 hours. |
| Weighing the oil | Subsequently, the separated oil is carefully weighed and expressed as a percentage of the test sample’s original mass. |